ESU16UG4020M2-0030 INFORTREND SCSI TO SCSI RAID ENCLOSURE
U320 SCSI-to-SCSI, 3U / 16-bay RAID array, Single controller with 256MB, ASIC 266, 4xSCSI ports, SCSI
Specifications
RAID
Multiple arrays configurable with dedicated or global hot spares
RAID levels supported: RAID 0, 1 (0+1), 3, 5, 10, 30, 50, and NRAID
Online expansion by:
Adding new drives
Copying and replacing drives with drives of larger capacity
Experienced RAID firmware with
IOSmart Technology
DrvSmart Technology
SysSmart Technology
Host Interface
Two (2) SCSI-320 through dual-stacked VHDCI 68-pin SCSI port; SCSI-160 backward compatible
Concurrent I/O commands
Tagged command queuing up to 256
Variable stripe size per Logical Drive
Optimization setting for random or sequential I/Os
Drive Interface
Sixteen (16) SCSI drive trays that accommodate 1-inch pitch, 3.5-inch SCSI-320 disk drives; SCSI-160 backward compatible
Automatic bad-sector reassignment
Drives hot-swappable
Dual channels across 16 drives within each subsystem
System Components
Redundant, hot-swappable components designed for no single point of failure
One (1) EonStor 3U enclosure
One (1) RAID controller module
One (1) 256MB or above DDR RAM DIMM module (pre-installed on the controller module)
Two (2), hot-swappable, redundant, 460W power supply units (PSUs)
Two (2) hot-swappable, dual-speed, redundant, dual-fan cooling modules
Sixteen (16) hot-swappable drive trays
Two (2) front handles; one (1) with LCD panel
Optional battery backup unit (BBU)
Management
Front LCD control panel for setup and configuration
10/100 BaseT Ethernet for out-of-band management
Auto on-lining of cascaded enclosures
RS-232C for local access to firmware-embedded utility
Firmware-embedded Java-based RAIDWatch ® GUI manager:
VT-100 terminal emulation via RS-232C
Telnet access via onboard Ethernet port
Cross-platform, remote administration with SSL
Out-of-band access via Ethernet
Centralized management to monitor and administer multiple RAID units on one screen
Configuration client for real-time event notification over Email, Fax, LAN broadcast, SNMP Traps, MSN messenger, ICQ, SMS short messages, and the configuration utility screen
Indicators
Onboard alarm is triggered when one of the following modules fails:
RAID controller module surpass the self-monitoring thresholds
Cooling module
PSU
BBU (if installed)
Hard drive
Module-status LED indicators:
Two (2) per drive tray
Two (2) per cooling module
One (1) per PSU
Three (3) per LCD panel
Four (4) per RAID controller module
Two (2) per Ethernet port
One (1) per BBU (if installed)
Module failure alert through I 2 C bus
IOSmart
IOSmart allows for the flexible configuration of logical drives, logical volumes and logical partitions and ensures instant RAID availability via background logical drive initialization. The firmware's embedded intelligent algorithms, such as Adaptive Write Policy and Guaranteed Latency I/O, improve the performance of sequential write applications and ensure the fast and continuous flow of data.
DrvSmart
The DrvSmart utility provides an easy way to store data while keeping it safe. One of the main DrvSmart functions, Media Scan, retrieves data from degraded or damaged hard drives and handles low quality drives in both the degraded mode and during the rebuild process. Other DrvSmart features include disk cloning, drive roaming, SMART, transparent resetting of non-responsive hard drives, and RAID parity update tracking and recovery.
SysSmart
In addition to RAID protection for the disk drives, Infortrend has developed a special firmware feature that automatically changes the data cache policy to write-through mode when abnormal conditions are detected such as a PSU/cooling module failure, low BBU or UPS battery charge, etc.
By using the firmware to control the rotation speed of the enclosure's dual-speed fans, the fan rotation speed is raised to a higher level when critical conditions are detected, e.g., a PSU or fan failure. Fan speed returns to the lower setting when normal operating status is restored. Control over caching behaviors, as well as voltage and temperature self-diagnostics, is also related to enclosure conditions.
Interfaces
Two (2) dual-stacked VHDCI SCSI ports
Two (2) audio jack RS-232C serial port (38400, n, 8, 1)
One (1) 10/100M Ethernet port
Power Supply Module
Two (2) redundant hot-swappable power supplies with PFC
|
|