ESA16FR243115-0030 INFORTREND 3U 16BAY FC-SATA DUAL CNTRL
Specifications
RAID
Multiple arrays with Dedicated, Global, or Enclosure-specific hot spares
RAID levels supported: RAID 0, 1 (0+1), 3, 5, 6, 10, 30, 50, 60, and NRAID
ASIC400 backbone
Online expansion by:
Adding new drives
Copying and replacing drives with drives of larger capacity
Automatic background rebuild
Configurable stripe size and write policy per array
Intelligent drive handling:
In degraded mode: skips irreparable blocks to continue rebuild
In normal operation: data-block verification and repair
Intelligent reactive and preventive mechanisms:
Automated cache flush
Automated Media Scan
Automated caching mode
System Components
Single or Redundant controller configuration
Compact steel and aluminum alloy enclosure
Two (2) or one (1) RAID controller modules
Three (3) hot-swappable, redundant, 405W power supply units
Two (2) hot-swappable, redundant, thermal fan cooling modules
Twenty-four (24) hot-swappable drive trays
Two (2) forearm handles
Two (2) hot-swappable battery backup units (BBUs)
Host Interface
Four (4) 4G-FC host channels with embedded bypass to eight (8) Fibre ports (A24F-R2430)
Two (2) 4G-FC host channels with embedded bypass to four (4) Fibre ports (A24F-G2430)
Tagged command queuing up to 256
Variable stripe size per logical drive
Optimization setting for random or sequential I/Os
Drive Interface
Twenty-four (24) hot-swappable 3Gbps SATA-II (3Gbps) drive trays
Automatic bad sector reassignment
Dedicated bandwidth to each connected drive
Management
Firmware-embedded utility via LCD keypad or RS-232C port
VT-100 terminal emulation via RS-232C
Telnet access via the onboard Ethernet port
10/100 BaseT Ethernet for out-of-band management
Two (2) COM ports for local access to firmware-embedded utility and UPS connectivity
Brower- or Java-based RAIDWatch® manager:
Graphical user interface
Local/remote management; in-band or out-of-band via TCP/IP
Centralized management to monitor and administer multiple RAID units on one screen
Secure link over SSL
Configuration Client for easy access to the configuration utility screen
SNMP 2.0 MIBs with get and set commands
SAN Management
Up to 1024 LUNs (if sufficiently large memory is used with the proper settings)
Indicators
Onboard alarm
Module status LED indicators:
Two (2) per drive tray
Three (3) per LCD panel
Seven (7) per RAID controller module
Two (2) per Ethernet port
Two (2) per cooling module
One (1) per power supply unit
One (1) per BBU module
Two (2) per FC port
Module failure alert through I2C bus
Event notifications sent over email, fax, LAN broadcast, SNMP traps, MSN messenger, SMS short messages
System alerts through Java-based RAIDWatch manager
Infortrend Smart Technologies
Derived from a decade of experience in RAID storage design, Infortrend's innovative firmware delivers Smart technologies that provide enhanced storage solutions for every customer environment, from small organizations to large enterprises. These technologies enhance I/O processing, drive handling, and system management.
IOSmart
IOSmart allows for the flexible configuration of logical drives, logical volumes and logical partitions and ensures instant RAID availability via background logical drive initialization. Fibre loops' load balancing is provided within the subsystem. The firmware' s Adaptive Write Policy and Guaranteed Latency I/O algorithms improve write performance and ensure fast and continuous data flow.
DrvSmart
The DrvSmart utilities manage disk drive defects and help ensure data integrity. One of the main DrvSmart functions, Media Scan, retrieves data from degraded or damaged hard drives and handles low quality drives in both the degraded mode and during the rebuild process. Other DrvSmart features include disk cloning, drive roaming, SMART, transparent resetting of non-responsive hard drives, RAID parity update tracking and recovery.
SysSmart
SysSmart combines enclosure monitoring and firmware management capabilities in order to minimize the chance of down time caused by hardware failures. The SysSmart functions include the event-triggered cache flush and the various monitoring approaches combined with the powerful RAIDWatch manager. Component status, voltage and temperature readings, and system events are instantly revealed through the manager's graphical interface.
|
|