ESA24UG242115-0030 INFORTREND 4U 12 BAY SCSI-SATA II
Specifications
RAID
Multiple arrays configurable with dedicated or global hot spare drives
RAID levels: RAID0, 1 (0+1), 3, 5, 6, 10, 30, 50, 60, and NRAID
Online expansion by:
Adding new drives
Copying and replacing drives with drives of larger capacity
Automatic background rebuild
Configurable stripe size and write policy per array
Intelligent drive handling:
In degraded mode: skips irreparable blocks to continue rebuild
In normal operation: data-block verification and repair
System Components
Single RAID controller configuration provides full-featured RAID functionality
One (1) 4U enclosure
One (1) RAID controller module
One (1) 512MB DDR RAM DIMM module preinstalled on the controller module; system supports 512MB to 2GB capacity DIMM modules
Three (3, N+1) hot-swappable, redundant, 405W power supply units
Twenty-four (24) hot-swappable drive trays
Two (2) hot-swappable, redundant cooling modules
Two (2) forearm front handles
One (1) optional battery backup unit (BBU)
Host Interface
Two (2) SCSI-320 host channels interfaced through two (2) dual-stacked VHDCIs
Tagged command queuing up to 256
Host-side ordered tag support
Drive Interface
Twenty-four (24) hot-swappable 3Gbps SATA II drive trays that accommodate 1-inch pitch SATA II or SATA I disk drives
Native Command Queuing (NCQ) support
Dedicated bandwidth to each connected drive
Automatic bad sector reassignment
Management
Firmware-embedded utility via LCD keypad or RS-232C terminal
10/100BaseT Ethernet for out-of-band management
Two (2) COM ports for local access to firmware-embedded utility and UPS connectivity
Telnet access via onboard Ethernet port
Java-based RAIDWatch® Manager
Graphical user interface
Local/remote management; in-band or out-of-band via TCP/IP
Centralized management of multiple subsystems from one management computer
A variety of event notification methods via the Configuration Client sub-module: email, fax, LAN broadcast, SNMP traps, MSN messenger, ICQ, and SMS short messages
Secure link over SSL
Indicators
Onboard alarm
Module status LED indicators
Two (2) per drive tray
Two (2) per cooling module
One (1) per power supply unit
One (1) per BBU module
Three (3) per LCD panel
Four (4) per RAID controller module
Two (2) per Ethernet port
Module failure indication and temperature/voltage readings through I2C bus
|
|